Shipped very fast,and was very helpful,New and Original,would highly recommend.
—— Nishikawa From Japan
Professional and fast service,acceptable prices for goods.
excellent communication,product as expected.
I highly recommend this supplier.
—— Luis From United States
High Quality and Reliable Performance: "The electronic components we received from [ShenZhen Mingjiada Electronics Co.,Ltd.] are of high quality and have shown reliable performance in our devices."
—— Richardg From Germany
Competitive Pricing: The pricing offered by is very competitive, making it an excellent choice for our procurement needs.
—— Tim From Malaysia
The customer service provided by is excellent. They are always responsive and helpful, ensuring our needs are met promptly.
—— Vincent From Russia
Great prices, fast delivery, and top-notch customer service. ShenZhen Mingjiada Electronics Co.,Ltd. never disappoints!
—— Nishikawa From Japan
Reliable components, fast shipping, and excellent support. ShenZhen Mingjiada Electronics Co.,Ltd is our go-to partner for all electronic needs!
—— Sam From United States
High-quality parts and a seamless ordering process. Highly recommend ShenZhen Mingjiada Electronics Co.,Ltd for any electronics project!
—— Lina From Germany
I'm Online Chat Now
Company BLOG
Supply ICs Chip 4 Channel AFE49I30YZR Ultra-Small Integrated Analog Front End - AFE 24 Bit 30-DSBGA
Supply ICs Chip 4 Channel AFE49I30YZR Ultra-Small Integrated Analog Front End - AFE 24 Bit 30-DSBGA
Product Description Of AFE49I30YZR
The AFE49I30YZR is an analog front-end for optical bio-sensing/ PPG and ECG measurement applications. The device supports up to six switching light-emitting diodes (LEDs) and up to four photodiodes. Up to 24 signal phases can be defined and the PPG or ECG signals can be acquired from each phase in a synchronized manner.
Specification Of AFE49I30YZR
Part Number:
AFE49I30YZR
Applications:
1-lead ECG, Optical-HRM
Resolution (Bits)
22
Number Of LEDs
6
Interface Type
I2C
Operating temperature range (°C):
-40 to 85
Features Of AFE49I30YZR
Supports signal acquisition of up to 24 phases
Flexible allocation of 6 LED, 4 PD in each PPG phase
Synchronized PPG/ECG signal acquisition with each phase configurable as PPG or ECG, and at different data rates
Synchronized PPG/ECG supports up to 1 kHz data rate
ECG-only mode supports up to 4 kHz data rate
PPG signal chain:
System SNR up to 108-dB at 16 µA PD current
Low current for continuous operation on a wearable device with a typical value: 15 µA for an LED, 20 µA for the receiver
PPG Transmitter:
Supports common anode LED configuration
8-Bit programmable LED current with range adjustable from 25 mA to 250 mA
Mode to fire two LEDs in parallel with independent per-phase current control
Programmable LED on-time per-phase
Simultaneous support of 6 LEDs for SpO2, HRM, or multi-wavelength HRM
PPG Receiver:
Supports 4 time-multiplexed photodiode inputs
2 parallel receivers to sample two PD channels simultaneously
Individual ambient offset subtraction DAC at each TIA Input with 8-bit per-phase control and range adjustable up to 255-µA
Individual LED offset subtraction DAC at each TIA input with 5-bit per-phase control and
15.5-µA range
Close to 100 dB ambient rejection up to 10 Hz
Noise filtering with programmable bandwidth
Transimpedance Gain: 3.7 kΩ to 1 MΩ
ECG Signal Chain
1-lead ECG with RLD output for bias
INA gain programmable from 1.6 – 13
<1 µVrms input noise (in a 1-150 Hz bandwidth) at 4-kHz sample rate
Integrated 450 Hz Low Pass Filter
AC, DC lead-off detect with 3.125-100 nA current and programmable interrupt
Supports external clock and internal oscillator modes
Option to acquire data synchronized with a system master clock
Automatic cancellation of DC from ambient, LED
FIFO with 128-sample depth
I2C interface
2.6-mm × 2.1-mm DSBGA, 0.4-mm pitch
Supplies: Rx: 1.7 V-1.9 V (LDO bypass); 1.9 V-3.6 V (LDO enabled), Tx: 3 V-5.5 V, IO: 1.7-3.6 V
Supports operation with 2 supplies - 1.8 V, 5 V
Applications Of AFE49I30YZR
ECG on a wearable device
Synchronized PPG, ECG for PTT-based Blood pressure
Optical heart-rate monitoring (HRM) and Heartrate variability (HRV) for wearables, hearables
Pulse oximetry (SpO2) measurements
Maximum oxygen consumption (VO2 Max)
Simplified Schematic Of AFE49I30YZR
FAQ
Q: Are your products original?
A: Yes, all products are original, new original import is our purpose.
Q: Which Certificates do you have?
A: We are ISO 9001:2015 Certified Company and member of ERAI.
Q: Can you support small quantity order or sample?Is the sample free?
A: Yes,we support sample order and small order.Sample cost is different according to your order or project.
Q: How to ship my order? Is it safe?
A: We use express to ship,such as DHL,Fedex,UPS,TNT,EMS.We can also use your suggested forwarder.Products will be in good packing and ensure the safety and we are responsible to product damage to your order.
Q: What about the lead time?
A: We can ship stock parts within 5 working days.If without stock,we will confirm lead time for you based on your order quantity.